Uvi Sağlık, sağlık profesyonelleri için en iyi ürünleri kusursuz bir tedarik zinciriyle sunmaya gayret gösteren bir şirket.

Shopping cart

Subtotal $0.00

View cartCheckout

Single-Stage Dilation Balloons

dilation balloons wire guided single stage balloons 580x580
dilation balloons wire guided single stage balloons 1 580x580

As regards manufacture, MICRO-TECH produces all the dilation balloons itself – using state of the art European and American production technology. Excellent workmanship and the use of premium materials, ensure that the MICRO-TECH balloons achieve the highest possible quality standard. MICRO-TECH's dilation is also top of the range. The balloons are characterized by a series…

As regards manufacture, MICRO-TECH produces all the dilation balloons itself – using state of the art European and American production technology. Excellent workmanship and the use of premium materials, ensure that the MICRO-TECH balloons achieve the highest possible quality standard.

MICRO-TECH's dilation is also top of the range. The balloons are characterized by a series of features that guarantee maximum therapeutic success. For instance, two X-ray markings indicate the precise working length of the balloon, thereby ensuring its precise positioning.

Under the application of pressure, the balloon very rapidly acquires its precisely predefined expansion width. Furthermore, the high-pressure design ensures that the balloon retains its shape over the entire working length, thereby allowing optimum dilation success.

All balloons are available as TTS (through-the-scope) systems up to a balloon diameter of 18 mm. The required working channel diameter is at least 2.8 mm.

Wire Guided Single-Stage Balloons

Successful in practical use

Stenoses are effectively dilated using the MICRO-TECH dilation balloons. The balloon dilates the stenosis safely and gently and prepares the area to be treated in an optimum manner. The uniform distribution of pressure over the entire working length of the balloon and the outstanding dimensional stability during dilation guarantee excellent therapeutic success over the entire length of the stenosis.

KEY BENEFITS

  • dimensionally stable high pressure design

  • 2 X-ray markings

  • separate guide wire and insufflation lumens

  • conical shaped catheter tip

  • very rapid expansion

  • guide-wire compatible up to 0.035 inches

Fixed wire esophageal multi-stage balloons
REF Ballon Inflate O.D. Ballon length (mm) Inflation Pressures Channel Size (mm) Catheter Size (Fr) Catheter Length (cm) Packaging
(mm) (Fr) (atm) kpa
FWB-06/80-6/18-M 38906 18-21-24 80 37782 304-608-1013 ≥2.8 6 180 2/Box
FWB-08/80-6/18-M 39701 24-27-30 80 3-5.5-9 304-557-912 ≥2.8 6 180 2/Box
FWB-10/80-6/18-M 40494 30-33-36 80 37749 304-507-811 ≥2.8 6 180 2/Box
FWB-12/80-6/18-M 12-13.5-15 36-40.5-45 80 3-4.5-8 304-456-811 ≥2.8 6 180 2/Box
FWB-15/80-6/18-M 15-16.5-18 45-49.5-54 80 3-4.5-7 304-456-709 ≥2.8 6 180 2/Box
FWB-18/80-6/18-M 18-19-20 54-57-60 80 3-4.5-6 304-456-608 ≥2.8 6 180 2/Box
Fixed wire esophageal single-stage balloons
REF Ballon Inflate O.D. Ballon length (mm) Inflation Pressures Channel Size (mm) Catheter Size (Fr) Catheter Length (cm) Packaging
(mm) (Fr) (atm) kpa
FWB-06/80-6/18-S 6 18 80 38146 405-608-811 ≥2.8 6 180 2/Box
FWB-08/80-6/18-S 8 24 80 38146 405-608-811 ≥2.8 6 180 2/Box
FWB-10/80-6/18-S 10- 30 80 38146 405-608-811 ≥2.8 6 180 2/Box
FWB-12/80-6/18-S 12 36 80 3-4.5-6 304-456-608 ≥2.8 6 180 2/Box
FWB-15/80-6/18-S 15 45 80 2.5-4-5 253-405-507 ≥2.8 6 180 2/Box
FWB-18/80-6/18-S 18 54 80 37319 203-304-405 ≥2.8 6 180 2/Box